I run the adaptronic on my rb20det made 320hp on 18psi with a 2876r on the side of it. Appears very easy to use, has Self tuning and closed loop only downside which really isn't to much of a downside is it only has 4 injector outputs, But this will be changed in the new model comming out next year. Tacholink generates vehicle movement data, temperature readings, driver identification, vehicle security and immobilisation, and detailed incident recordings. The device constantly receives data from sensors installed in the vehicle. These can include vehicle speed, engine RPM, acceleration, vehicle odometer readings, fuel levels and GPS position. . 440 Adaptronic firmware vers. 10.064 or later installed and software setup. Plug -in (all models) Adaptronic firmware vers. 10.064 or later installed and softwar e setup. Specific firmware version with preset 38400 baud e1280s rate installed. This firmware can only be provided by Adaptronic: no software setting is available. Adaptronic ECUs; Select your Vehicle. Rotary Engine Parts. New Engines; Rotor Parts. 74-85 Rotor Parts; 86-95 Rotor Parts; Rx8 Rotor Parts; 20B Rotor Parts; Gasket Kits. 69-73 10A & 12A; 74-78 13B; 79-85 12A; 84-85 13B; 86-88 13B Non-Turbo; 87.
This product is one of the first wire-in ECUs that Adaptronic has for the new line of Modular ECUs.
The main objective in creating the Adaptronic Modular ECU line is to work towards Adaptronic’s mission which is to give people control. In doing this, we came up with a system which would give people greater flexibility and at the same time, overcome the limitations of the previous product lineup( select ecus).
Technical hardware specs;
2X 32B 120MHZ processors; 1 per control board, and 1 per big output module( each additional optional module has its own 32MB 120MHZ processor, so processor speeds never slow down with expansion)
M2000 has space for 1 small modular( a total of 3X 120MB processors)
On average the new Modular units are 2 to 3x faster than its current competitors latest offerings( before any additional modules, M6000 fully loaded is 3x faster than the fastest aftermarket ecu we are are of).
IP67 rated water proof connection with (1) 32 pin & (1) 26 pin super seal waterproof wiring connectors.
Features
can be expanded or upgraded to use one of the following boards:
- DBW / e-throttle controller
- Mini Output Board (6 x push-pull aux)
- Mini Analogue Input Board (4 x analogue inputs)
- Mini Real-Time Input (6 x inputs)
– So you can do another 2 x CAS (giving 5 total), 3 x VSS (giving 4 total), 1 x flex - Lambda Controller
- EGT Inputs
Asahi Optical Driver Download for windows. Control board (1 per ECU)
VariableNumberDetails Analogue 0-5V inputs 11 Each is 0 – 5.5V, 55k input impedance
- 2 x TPS / pedal position
- 6 x pressure – Oil, Fuel, Internal intake MAP, internal exhaust MAP, external intake MAP, external exhaust MAP
- 3 x spare for servo feedback / external inputs
Analogue oxygen sensor inputs 2 Each can be either:
- 0 – 5.5V, 55k input impedance
- 0- 3.3V, 1M input impedance
Temperature inputs 4 Each is 0 – 5.5V, 55k input impedance to ground Each can be:
- Non-biased, eg in piggyback mode. Calibration is in mV
- Biased, calibration is in Ohms. 3 internal pull-ups, 1k5, 2k2, 4k7, automatically selected by the ECU
Manifold air temperature, coolant temperature, oil temperature, fuel temperature
Crank trigger inputs 3
- Selectable 2k2 pullup (on in digital mode, off in reluctor mode)
- Variable voltage trigger threshold from 0 to 65V – either arm input for reluctor or threshold for digital input
- AC coupled zero crossing trigger in reluctor mode
- Variable filtering 1 to 192 µs
- See built-in scope section
Vehicle speed input 1
- Selectable 2k2 pullup
- Variable voltage trigger threshold from 0 to 65V
- Variable filtering 1 to 192 µs
- See built-in scope section
Sensor power and ground
- 5V regulated output for sensors, max 100 mA, current limited (voltage is monitored by ECU)
- Sensor ground connected to ground inside ECU under firmware control to detect external ground loops in the wiring (voltage is monitored by ECU)
Adaptronic Driver Licence
- 50 k input impedance
- Sampled at 80 kHz (12-bit resolution, 3.3V peak to peak max voltage),
- Variable second order highpass and lowpass filters
- Selectable start and end of sampling windows (in crank angle)
Wired Outputs 2
- Dedicated outputs for tacho and EFI relay
- Tacho output has inductor to generate back-EMF spike for impulse tachometers.
- EFI relay output can be configured as fuel pump or EFI relay. Switches to ground, current limited to 600 mA
- Up to 1 Mbps
- Internal 120 Ohm terminating resistor can be turned on and off with ECU setting on each channel
- Standard USB mini AB connector.
- 12 Mbps max speed
- USB appears as mass storage device (USB stick); no drivers are necessary
- Software installer included on mass storage device
Adaptronic Usb Driver
- All 4 use 4-pin Molex connectors
- 2 x serial in (ground, transmit, receive)
- 1 x serial out (ground, transmit, receive)
- 1 x controller out (ground, transmit, receive and 12V switched, current limited power) – eg for dash, hand controller
- Access point
- 230kbps max speed
- Settings and live data only (no log retrieval due to speed)
Inbuilt sensors
- Microphone
- 3 axis accelerometer
- 3 axis rate gyro
Inbuilt logging 32 MB ( 32678 KB)
- Max 30 hrs @ 10 Hz( 100 m/s sample rate) , 13 channels
- Min 20 mins @ 100 Hz( 10m/s sample rate), 125 channels
Exception (fault) detection 16 MB Separate logging memory for storing logs during “exceptions” (sensor / trigger faults etc) Built-in scope 4 channels
- Max sample rate 200 kHz (5µs sample period)
- 1000 samples per screen (min 5ms across the screen)
- Analogue trigger inputs sampled at 40 kHz
- Analogue CAS inputs
- Peak detected CAS voltages
- CAS threshold voltages
- Filtered CAS inputs
- Analogue external inputs
- Raw and filtered knock waveforms
- Current engine angle
- Calibrated input values
- Intermediate calculation values
- Output calculated values
Output Module (1 per ECU)
Number of injector outputs
Switching topology for low heating Peak and hold current waveforms Programmable peak and hold current Max current per channel 4A continuous Nominal current per channel 1A (can be controlled in software) Unused injector outputs can be configured as auxiliary outputs, PWM capable, but only switching to ground Output voltage and current monitored Appears as a 470 Ohm to supply when high, short to ground when low Current limited output Unused injector outputs can be configured as auxiliary outputs, PWM capable, but only switching to ground, and only low current Voltage and current monitored Push-pull outputs (can drive high or low) High side current limited to 1.2A Low side current up to 4A continuous Can be PWM but not engine synchronous Voltage and current monitored Mini Output Module (1 or more per ECU, max 2) Push-pull outputs (can drive high or low) High side current limited to 1.2A Low side current up to 4A continuous Can be PWM but not engine synchronous Voltage and current monitored